  lpt50-m series 55 watts total power: 47 - 55 watts input voltage: 90 - 264 vac 127 - 300 vdc # of outputs: triple special features ? medical safety approvals ? universal input ? 2 x 4 footprint ? less than 1u high ? overpower and short circuit protection ? high effciency ? high mtbf ? built in emi flter (cispr 22 class b) ? led power good indicator ? input power < 74 watts ? complies with en61000 -3-2 ? 85 khz switching frequency ? dual ac fuses ? ul class i approved ? lpx100 enclosure kit available ? rohs compliant safety ? ul: ul 60601-1 ? csa: csa-c22.2 no. 601.1-m90 ? vde: en60601-1 ? ce: lvd electrical specifcations input input range 90 - 264 vac (wide range) 127 - 300 vdc frequency 47 - 440 hz inrush current < 60 a peak @ 230 vac, cold start @ 25 c effciency 80% typical at full load emi/rfi fcc class b conducted; cispr 22 class b conducted; en55022 class b conducted, en60601-1-2 safety ground leakage current 275 a @ 50/60 hz; 264 vac input output maximum power 55 w for convection (lpt51, 47.4 w) hold-up time 10/20 ms 115/230 vac input line overpower protection short circuit protection on all outputs. case overpower protected @ 110-160% of normal rating overvoltage protection 30-50% above nominal output data sheet environmental specifcations operating temperature 0 c to 50 c ambient. derate each output as 2.5% per degree from 50 c to 70 c. -20 c startup storage temperature -40 c to +85 c electromagnetic susceptibility designed to meet en61000-4; -2, -3, -4, -5, -6, -8, -11 level 3 humidity operating; non-condensing 10% to 95% rh vibration iec68-2-6 to the levels of iec721-3-2 mtbf demonstrated > 550,000 hours at full load and 25 c ambient conditions power
ordering information model number output voltage minimum load maximum load with convection cooling peak load 1 regulation 2 ripple p/p (pard) 3 LPT51-M +3.3 v +5 v +12 v 0.8 a 0.1 a 0 a 8 a 3 a 0.5 a 9 a 4 a 1 a 2% 6% 5% 50 mv 50 mv 120 mv lpt52-m +5 v +12 v -12 v 0.5 a 0.1 a 0 a 8 a 3 a 0.5 a 9 a 4 a 1 a 2% 5% 5% 50 mv 120 mv 120 mv lpt53-m +5 v +15 v -15 v 0.5 a 0.1 a 0 a 8 a 2.4 a 0.5 a 9 a 3.2 a 0.7 a 2% 5% 5% 50 mv 150 mv 150 mv lpt54-m +5 v +24 v +12 v 0.5 a 0.1 a 0 a 8 a 1.5 a 0.5 a 9 a 2 a 0.7 a 2% 7% 5% 50 mv 240 mv 120 mv pin assignments connector LPT51-M lpt52-m lpt53-m lpt54-m sk1-1 line line line line sk1-3 neutral neutral neutral neutral sk2-1 +3.3 v +5 v +5 v +5 v sk2-2 +3.3 v +5 v +5 v +5 v sk2-3 common common common common sk2-4 common common common common sk2-5 +12 v -12 v -15 v +12 v sk2-6 5 v +12 v +15 v +24 v mating connectors ac input molex 09-50-8031 (usa) 09-91-0300 (uk) pins: 08-52-0113 dc outputs molex 09-50-8061 (usa) 09-91-0600 (uk) pins: 08-52-0113 artesyn embedded technologies connector kit #70-841-006, includes all of the above 1. peak current lasting < 15 seconds with a maximum 10% duty cycle. 2. at 25 c including initial tolerance, line voltage, load currents and output voltages adjusted to factory settings. 3. peak-to-peak with 20 mhz bandwidth and 10 f (tantalum capacitor) in parallel with a 0.1 f capacitor at rated line voltage and load ranges. 4. this product is a component power supply and is only for inclusion by professional installers within other equipment and must not be operated as a standalone product. emc compliance to appropriate standards must be verifed at the system level. this product is for sale to oems and system integrators, including through distribution channels. it is not intended for sale to end users. lpt50-m series data sheet
worldwide offices americas 2900 s.diablo way tempe, az 85282 usa +1 888 412 7832 europe (uk) waterfront business park merry hill, dudley west midlands, dy5 1lx united kingdom +44 (0) 1384 842 211 asia (hk) 14/f, lu plaza 2 wing yip street kwun tong, kowloon hong kong +852 2176 3333 for more information: www.artesyn.com/power for support: productsupport.ep@artesyn.com artesyn embedded technologies, artesyn and the artesyn embedded technologies logo are trademarks and service marks of artesyn embedded technologies, inc. all other names and logos referred to are trade names, trademarks, or registered trademarks of their respective owners. ? 2016 artesyn embedded technologies, inc. all rights reserved. for full legal terms and conditions, please visit www.artesyn.com/legal. www.artesyn.com lpt50-m series-ds 21mar2016 mechanical drawing 2.00 [50.8] 1.72 [43.8] 4.00 [101.6] 3.73 [94.7] 1.30 [32.9] 0.197? (5.0) minimum s tandoff h eight m ax . s c rew he ad diameter .22? (5.6) 1 3 1 6 m1 m2 gnd mounting hole ?4.0(4x) notes: 1. specifcations subject to change without notice. 2. all dimensions in inches (mm), tolerance is 0.02(0.5mm) 3. mounting holes m1 and m2 should be grounded for emi purposes. 4. mounting hole m1 is safety ground connection. 5. specifcations are for convection rating at factory settings at 115 vac input, 25 c unless otherwise stated. 6. warranty: 2 year 7. weight: 0.45 lbs/0.20 kg lpt50-m series data sheet


▲Up To Search▲   

 
Price & Availability of LPT51-M

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X